Metal roof installation in University Park, TX

University Park Metal Roofing for Period Homes and Rebuilds

Standing seam, slate and tile roofs are a common sight on University Park streets near SMU, and the city’s houses give metal a lot to work with. On its 1920s-40s Tudors and Georgians and on the large 2000s-2020s rebuilds that replaced many of them, Permanent Metal Roofing Systems installs standing seam, both snap lock and mechanical lock, in copper, zinc, aluminum or steel, plus metal slate and shake profiles. The city lies in Dallas County directly north of Highland Park, roughly 9 miles from our Mesquite office.

  • 20+ years of experience
  • Lifetime limited warranty
  • Free written estimates

Roof Types We See Around University Park

Two kinds of house define University Park. The first is the 1920s-40s Tudor or Georgian in Volk Estates or University Heights: a Tudor with steep, crossing gables, dormers and tall chimneys, a Georgian with a calmer hipped roof and a formal cornice, both often roofed in slate or tile whose valley and chimney flashing gives out long before the stone does. The second is the large rebuild on a cleared lot, frequently with low-slope sections, parapets and modern massing. Metal slate or copper accents keep a Tudor true to its period, 1-inch mechanical lock gives a Georgian a traditional metal look, and zinc or dark PVDF steel in 1.5-inch mechanical lock covers a rebuild’s low slopes.

We work in Caruth Hills, University Heights, Volk Estates and the blocks around Snider Plaza, from the Southern Methodist University campus east to US-75 Central Expressway.

University Park Hail, Wind and Heat: What a Roof Faces

The June 13, 2012 storm was at its worst over University Park, dropping baseball-size hail in an event that produced heavy insured losses across Dallas County. Any new roof here should be planned with the next one in mind. Makers of stone-coated steel and several metal shake lines rate them UL 2218 Class 4. With standing seam, heavier 24- or 22-gauge steel limits cosmetic dents, while copper and zinc are softer and can show marks from large hail even as they keep water out. Each insurer sets its own Class 4 credit. Concealed clips are spaced tighter at corners and edges, where uplift is highest.

  • Impact-rated standing seam, stone-coated steel and metal shingle options
  • Heavier 24-gauge panels that resist cosmetic hail dents better than thinner steel
  • Clip spacing and fastening planned for Texas wind uplift

See how Class 4 impact-rated metal roofing works, what to do about hail damage and insurance claims, or compare standing seam systems and stone-coated steel.

Roof Systems for University Park Homes and Buildings

University Park is where our architectural metals matter most. On the low-slope parts of modern rebuilds, mechanical lock in zinc, copper or PVDF steel is the right panel, made to the full length of each slope. On Tudor and Georgian restorations, metal slate and copper details do the work, and flat lock or diamond panels can wrap a curved bay or dormer. We bend the valley, chimney and wall flashing in our shop from the same metal as the roof, so every detail matches.

Standing Seam Roofs

Hidden-clip standing seam in 24-gauge Galvalume, aluminum, copper or zinc, with Kynar 500 finishes built for Texas sun.

Stone-Coated Steel

DECRA shake, shingle and tile profiles that keep a traditional look on University Park homes in HOA neighborhoods.

Metal Shingles and Shakes

EDCO and Classic Metal Roofing Systems shingle and shake profiles in colors that suit brick and stone.

Corrugated and PBR Roofs

Ribbed panels for barns, shops and porch roofs, cut to the length of each run before they reach the site.

Copper and Zinc Roofing

Natural copper and zinc in standing seam, flat lock or diamond panels for whole roofs, bays and turrets.

Metal Roof Repair

Leaks at seams, screws, pipe boots and flashing traced and fixed on University Park metal roofs, ours or not.

Every University Park roof is priced from its own measurements. The metal roof cost guide explains which choices move the number most, from pitch and tear-off to profile and metal.

Premium Metal Roofing for University Park Custom Homes

About half of University Park’s housing was built in 1990 or later, according to Census estimates, a measure of how many prewar homes have been replaced on the same lots. The zoning code shapes those newer houses from the roof down. A principal house stops at 35 feet, and depending on lot width, any roof steeper than 14/12 to 16/12 counts as wall, so designers tuck a third floor under steep slopes broken by dormers; third-floor dormers facing a side lot line are held to 6 feet wide. For metal, that means tall planes seen up close from the sidewalk and many small roofs to flash. Narrower panels with striated or pencil-ribbed pans keep a steep plane from looking wavy, and every dormer cheek gets flashing bent to its own measurements.

  • Panel width and seam spacing chosen for tall, steep planes that neighbors see from the sidewalk
  • Each dormer cheek, sidewall and apron flashed in metal bent to its measured size
  • Striated or pencil-ribbed pans on wide planes, so a steep roof shows no waviness
  • Impact-rating paperwork kept with the roof records, since each insurer decides what proof it accepts

Compare copper and zinc roofing, architectural standing seam and the warranties that come with each system.

Permits and Design Review for a University Park Metal Roof

University Park has no HOAs. Exterior work and materials are governed instead by the city’s own building and zoning codes, which are strict, so Texas Property Code 202.011, the HOA roofing statute, does not come into play the way it does in the suburbs. What matters here is the city’s review. We check the requirements for your address, prepare the product data and roof details that your architect or the city may ask for, and obtain the permit wherever University Park requires one.

University Park Coverage Snapshot

CountiesDallas County
ResidentsRoughly 25,000
Typical homemedian value $1.86 million; half built in 1990 or earlier (Census ACS 2020-2024)
From our baseAbout 9 miles from Mesquite
Roof systemsStanding seam, metal shingles and shakes, stone-coated steel, corrugated and PBR, copper and zinc
ServicesNew roofs, replacements, repairs and hail damage documentation
Estimate and warrantyFree, measured and itemized in writing; lifetime non-prorated limited warranty on PMRS standing seam, transferable one time

The PMRS Difference in University Park

  • Written, itemized estimates that spell out panel, gauge, finish, underlayment and trim.
  • Our own installation crews, scheduled from our Mesquite office, never subcontractors.
  • A lifetime non-prorated limited warranty on PMRS standing seam roofs, transferable one time. See our warranties.
  • Class 4 impact-rated systems and the product documentation insurers ask for.
  • Your deductible stays your deductible. Texas law bars roofers from covering it, and we comply.

University Park Metal Roof Questions

Zinc or copper for a modern Park Cities rebuild?

Either works in our mechanical lock panels. Zinc ages to a quiet blue-gray that sits well on spare, modern facades. Copper darkens to brown and slowly toward green, which warms brick and stone. Each needs a solid deck and is seamed by machine, and once a roof like this has been seamed to specification, the owner can choose to buy an optional third-party weather-tightness warranty for it.

Can a University Park Tudor keep its period look with metal?

Yes. Metal slate profiles reproduce the scale and shadow lines of slate at a fraction of its weight, and copper on bays, dormers and entry roofs suits the architecture. Chimney and valley flashing can be bent from copper to match. The aim is a roof that looks as though it came with the house, not one added decades later.

Would metal have come through University Park’s June 2012 hail?

Most likely it would have kept the water out, though not without marks. Baseball-size stones crack slate and tile, while metal tends to dent instead, and a dent that does not leak is cosmetic. The UL 2218 Class 4 test judges cracking and rupture, not appearance. Heavier gauges and textured stone-coated finishes hide marks best, and your policy may treat cosmetic damage differently, so read it first.

Does PMRS repair metal roofs in University Park that another company installed?

Yes. We trace leaks at seams, screws, pipe boots and flashing on standing seam, PBR, corrugated and metal shingle roofs, whoever put them on, and explain the cause before we fix it.

Close to University Park, Also on Our Schedule

The full list lives on our DFW service areas page, and the office details are on our Mesquite location page.

Ready for a Permanent Roof in University Park?

Send the form for a written University Park estimate, or call (469) 466-2421 and talk it through with the company that forms and installs the roof.